running 2 sets of spotties on 1 relay

Post by 83-mud-lux »

i got a set of rectangle spotties on the headboard of the lux and just got another set of round ones but they didnt come with a relay.
im going to put them on the same switch but im not sure if i can run them through the same relay..also less wiring to do..help would be much appreciated thanks..smiley..
1991 2.8 turbo,ruf,patrol rear springs,inverted 14'' bilsteins,33's,rear locker,winch,sliders plus more...

TUFF MUD 4X4 CLUB!! RIDIN IT DIRTY
Posts: 613
Joined: Fri Oct 21, 2005 9:33 pm
Location: virginia, brisbane

Post by ausoops »

a 12v30A relay costs about $10, do it right, you will destroy your wiring and existing relay if you try to double up on the one circuit.
swb safari
Posts: 4426
Joined: Mon Mar 22, 2004 4:39 pm
Location: Sunshine Coast

Post by bru21 »

Watts = volts x amps.

assume 1 light is 100 watts
2 lights is 200 watts
4 lights are 400 watts

now divide the energy needed in watts (400) by the voltage supplied - (use the lower voltage to be safe ie 12v not 13.6 running voltage)

400 / 12

=33.33 Amps

Therefore assuming the relay is the limiting factor

a 30A relay (at 12v) would be too small.
a 40A relay would be adequate.

You need to see also if the wiring can handle it etc..

V = IR etc or Narva site etc

http://en.wikipedia.org/wiki/Ohm%27s_law

http://www.howstuffworks.com/question501.htm
ADHD Racing would like to thank
Mrs Bru @ Sunshine Coast Developmental Physiotherapy - www.scdphysio.com.au , Ryano @ Fourbys www.generaltire.com.au Blitzkrieg Motorsport
Posts: 396
Joined: Mon Dec 08, 2008 8:17 pm
Location: elimbah,qld

Post by 83-mud-lux »

thanks bru21.
all to technical for me but i got eventually haha.
i will get a 40amp relay tomorrow.yea its pretty good wiring set-up i got..
1991 2.8 turbo,ruf,patrol rear springs,inverted 14'' bilsteins,33's,rear locker,winch,sliders plus more...

TUFF MUD 4X4 CLUB!! RIDIN IT DIRTY
Posts: 4426
Joined: Mon Mar 22, 2004 4:39 pm
Location: Sunshine Coast

Post by bru21 »

make sure the relay holder is rated to 40 also, it will die if its not. Also I always choose a s/h ford relay over a narva etc as you cannot match oem quality
ADHD Racing would like to thank
Mrs Bru @ Sunshine Coast Developmental Physiotherapy - www.scdphysio.com.au , Ryano @ Fourbys www.generaltire.com.au Blitzkrieg Motorsport
God of Athiests
Posts: 8336
Joined: Thu Aug 07, 2003 2:14 am
Location: Brownsville

Post by DamTriton »

Globes can draw about 50% more amps on startup (1-2 secs). Two 30 amp relays would be better as you will only have 2 lights out if you blow fuses or a relay sh*ts itself. Cheaper in the longrun and easier to purchase and replace out in the sticks.
George Carlin, an American Comedian said; "Think of how stupid the average person is, and realise that half of them are stupider than that".
Posts: 19062
Joined: Sat Oct 25, 2003 11:39 pm
Location: In a horse near you

Post by chimpboy »

DAMKIA wrote:Globes can draw about 50% more amps on startup (1-2 secs). Two 30 amp relays would be better as you will only have 2 lights out if you blow fuses or a relay sh*ts itself. Cheaper in the longrun and easier to purchase and replace out in the sticks.
I agree, I would rather run two 30A relays than one 40A relay.

It is hardly any more work to install.
This is not legal advice.
Posts: 1990
Joined: Sun Jan 14, 2007 9:14 am
Location: Melbourne

Post by T_Diesel »

I woud wire each set on a 30A relay and fuse each relay individually. Better off doing it properly first up to avoid any hassles down the track.