Notice: We request that you don't just set up a new account at this time if you are a previous user.
If you used to be one of our moderators, please feel free to reach out to Chris via the facebook Outerlimits4x4 group and he will get you set back up with access should he need you.
Recovery:If you cannot access your old email address and don't remember your password, please click here to log a change of email address so you can do a password reset.

solution for air line breaking on rear air locker??

General Tech Talk

Moderators: toaddog, TWISTY, V8Patrol, Moderators

Post Reply
Posts: 568
Joined: Fri Nov 01, 2002 10:11 pm
Location: cranebrook, NSW

solution for air line breaking on rear air locker??

Post by Ryan »

Has anyone else had this prob? the blue air line keeps splitting just b4 it goes into the diff on my rear locker - have repaired it 5 times this will be number 6 - the air line's getting shorter each time lol... any ideas?? its a GQ diff if it makes a difference
Posts: 1857
Joined: Fri Feb 02, 2007 12:16 am
Location: ipswich

Post by nastytroll »

hydraulic line. ARB sell a HD airline kit @$86ea, I had 2 made with all fittings for $96 at LHS. Pertek or similar can do it too.
Posts: 568
Joined: Fri Nov 01, 2002 10:11 pm
Location: cranebrook, NSW

Post by Ryan »

genious :twisted: cheers mate thanks for the info
Posts: 283
Joined: Fri May 20, 2005 1:55 pm
Location: maitland

Post by matto »

i have a split in my line i'm going to try a few layers of heat shrink and see if that works
nissan 98 gu 5" lift 37 creepys, 80%reduction gears, front locker and a gen3 and no money.
Posts: 1857
Joined: Fri Feb 02, 2007 12:16 am
Location: ipswich

Post by nastytroll »

I changed my locker airline to 6mm and carry some spare tube and joiners. I have had no probs since the hyd hose though.
Posts: 14209
Joined: Sun Jan 11, 2004 11:36 am
Location: Adelaide

Post by -Scott- »

matto wrote:i have a split in my line i'm going to try a few layers of heat shrink and see if that works
100psi? I'd be surprised. It would be good to know if it works.
Posts: 2585
Joined: Fri Mar 28, 2008 4:45 pm
Location: SYDNEY

Post by thehanko »

-Scott- wrote:
matto wrote:i have a split in my line i'm going to try a few layers of heat shrink and see if that works
100psi? I'd be surprised. It would be good to know if it works.
no chance it will seal.

you would need to put it on and shrink it over wet silicon or epoxy or something, to actually seal the pressure.
*there's a rock, drive over it :) there's a bigger rock, drive over it :twisted: there's an even bigger rock, oops broke it :oops: Upgrade broken bit :bad-words:
Goto *
Posts: 3725
Joined: Wed Jun 30, 2004 1:45 pm
Location: Blue Mountains, or on a rig somewhere in bumf*ck idaho

Post by rockcrawler31 »

i know it was a pain for you to get fittings the right size but i am using 1/4 inch black nylon air line from compak just down the road from you. never had any dramas.

the old dude down there has LOADS of fittings available too
http://www.populationparty.org.au/
Posts: 1857
Joined: Fri Feb 02, 2007 12:16 am
Location: ipswich

Post by nastytroll »

fittings to do the swap to 6mm airline and 1/4 hyd line is easy, I can have a look and list whats needed if need be.
Posts: 3523
Joined: Fri Aug 27, 2004 12:27 am
Location: Fairfield,Sydney

Post by pongo »

all trucks use air lines these days, so joiners and replacment hose can be bought cheaply all over aust at any truck place. Even a few truckies carry joiners just in case. a quick cruise around a truck stop will usually get you a joiner.
Posts: 221
Joined: Sun May 18, 2008 9:00 am
Location: canberra

Post by blade 929 »

pongo wrote:all trucks use air lines these days, so joiners and replacment hose can be bought cheaply all over aust at any truck place. Even a few truckies carry joiners just in case. a quick cruise around a truck stop will usually get you a joiner.
sadley most trucks don't use 5mm hose they use 4mm or 6mm , probably be a good idea to change the line and fittings to something thats not arb specific . in saying that arb sell the joiners for $12 .

jai
set your limits way beyond your ability

member of COR4x4
Posts: 568
Joined: Fri Nov 01, 2002 10:11 pm
Location: cranebrook, NSW

Post by Ryan »

yea mite try some of the above ideas -- $12 from arb for the joiner is good but after 6 times it gets expensive lol
thanks for the info guys
Posts: 1663
Joined: Mon Nov 04, 2002 6:38 pm
Location: bethania QLD

Post by oozuk »

If your still running the rear swaybar it could be fouling on where the air locker line is, it's possible the lockers fitting was installed in a poor position and the line is getting damaged by the swaybar under suspension operation.

possible .....
Trying to finish the Zook

OOZUK buildup
http://www.outerlimits4x4.com/viewtopic.php?t=80949
***KING OF BLING***
Posts: 3523
Joined: Fri Aug 27, 2004 12:27 am
Location: Fairfield,Sydney

Post by pongo »

go the VDO, they are factory fitment for kenworth, they are easy to read at a quick glance, esp wehn you have 20 to look at.

Out of all the trucks ive driven the vdo's seem to be the easiest to read and are reliable, etc.
Posts: 14209
Joined: Sun Jan 11, 2004 11:36 am
Location: Adelaide

Post by -Scott- »

pongo wrote:go the VDO, they are factory fitment for kenworth, they are easy to read at a quick glance, esp wehn you have 20 to look at.

Out of all the trucks ive driven the vdo's seem to be the easiest to read and are reliable, etc.
OK. That's nice. Not particularly relevant, but nice.

Thanks.

:lol:
User avatar
Ice
Posts: 2429
Joined: Sun Jul 25, 2004 6:52 pm
Location: Central Coast, NSW

Post by Ice »

Drugs are bad Mmmm k pongo!

back on topic anyone else have any other options for replacement lines ?
xxxx wrote:
:bad-words: :snipersmile:
Posts: 6021
Joined: Sat Feb 15, 2003 11:01 pm
Location: Shed.

Post by dumbdunce »

-Scott- wrote:
matto wrote:i have a split in my line i'm going to try a few layers of heat shrink and see if that works
100psi? I'd be surprised. It would be good to know if it works.
100 psi is pretty low pressure, there's not a lot of force involved. a few layers will work.

we have some awesome heat shrink at work, it comes pre loaded with an internal layer of hot melt glue, but I don't know if it is available to people outside the electricity industry.
Free air locker to the first 20 callers!
Posts: 817
Joined: Fri Jun 17, 2005 9:23 pm
Location: Sydney

Post by TheOtherLeft »

dumbdunce wrote:we have some awesome heat shrink at work, it comes pre loaded with an internal layer of hot melt glue, but I don't know if it is available to people outside the electricity industry.
You can buy that glue/heatshrink stuff from Jaycar. Not sure if it's up to the same quality though.
Posts: 3523
Joined: Fri Aug 27, 2004 12:27 am
Location: Fairfield,Sydney

Post by pongo »

lol wrong thread, possibly even wrong forum.

Might have to start taking the drugs i just bought
Posts: 5256
Joined: Fri Jun 16, 2006 6:49 pm
Location: Melbourne

Post by Struth »

Get the equivalent size air tube in polyurethane tube not the usual hard plastic used by ARB (and most places).

Poly is much more flexible and less susceptible to breaking due to the suspensions movement.

You can get the tube from any good pneumatics supplier, look up Festo or Norgren for their nearest agent, take a sample of tube in ask for the same tube in polyurethane and that should solve the problem.

Cheers
Posts: 751
Joined: Tue Jul 24, 2007 8:55 pm
Location: GlassHouse Mountains

Post by taps »

Take the centre brass support tube out of the air line olive/fitting at the diff and run it without , you will have no more problems.
YOUR 4X4 ACTION
personalized 4x4 d.v.d's
"Let us capture your action" [url=http://au.youtube.com/watch?v=QefnzCt975c][b]Click Here To View Our Video Trailer[/b][/url]
Posts: 70
Joined: Wed May 20, 2009 5:47 pm
Location: WARNEET

change to 6mm

Post by tiny80 »

ive changed from 5mm plastic to 6mm copper lines all the way back to a mount on the crossmeber,
then run hyd 6mm to rear housing with extra lenght 200mm spring to keep it up .
then if some thing hits it the spring might brake but not the line i have never broken it yet in that time broke two brake hoses so it worked really well
Posts: 2480
Joined: Tue Mar 09, 2004 6:42 pm
Location: NSW

Post by r0ck_m0nkey »

TheOtherLeft wrote:
dumbdunce wrote:we have some awesome heat shrink at work, it comes pre loaded with an internal layer of hot melt glue, but I don't know if it is available to people outside the electricity industry.
You can buy that glue/heatshrink stuff from Jaycar. Not sure if it's up to the same quality though.
Or any electrical wholesaler.





Not stating the obvious here, but where your line goes into the fitting, do you have the protective spring that goes over the fitting and the first inch or two of the air line?
If God did not intend for us to eat animals, then why did he make them out of meat?
Posts: 1857
Joined: Fri Feb 02, 2007 12:16 am
Location: ipswich

Post by nastytroll »

r0ck_m0nkey wrote:
TheOtherLeft wrote:
dumbdunce wrote:we have some awesome heat shrink at work, it comes pre loaded with an internal layer of hot melt glue, but I don't know if it is available to people outside the electricity industry.
You can buy that glue/heatshrink stuff from Jaycar. Not sure if it's up to the same quality though.
Or any electrical wholesaler.





Not stating the obvious here, but where your line goes into the fitting, do you have the protective spring that goes over the fitting and the first inch or two of the air line?
A desent size stone will still crack the airline where the ferule is inside the nylon tube.
Post Reply

Who is online

Users browsing this forum: No registered users and 131 guests