ARB air locker not locking

General Tech Talk

Moderators: toaddog, TWISTY, V8Patrol, Moderators

Post Reply
Posts: 80
Joined: Thu Oct 01, 2009 12:52 am
Location: SA

ARB air locker not locking

Post by VHPirie »

My bro bought a Mav, which has an ARB air locker in the back. The previous owner ripped the switches, pump and wiring out. He bought an ARB pump (the small $200 one recommended for the job), but it doesn't seem to have enough pressure to engage the locker. Set the air compressor in the shed to about 90-100psi (I think, can't remember) and use that and it locks up, but the ARB pump won't lock it up?

Anyone know why this could be happening?
Posts: 1575
Joined: Thu Dec 28, 2006 6:50 pm
Location: Moronfield....

Post by nottie »

Have you contacted ARB yet :?:
More info on solinoids and such will help.
Posts: 43
Joined: Thu Nov 20, 2008 11:52 am
Location: melb

Post by ronno88 »

make sure that you have your fittings on the solonoids the rite way around no air might not be coming out.
Posts: 80
Joined: Thu Oct 01, 2009 12:52 am
Location: SA

Post by VHPirie »

Tried it with no solenoids and still no go. Nah didn't contact ARB, didn't even think of that to be honest haha. :P
Posts: 1575
Joined: Thu Dec 28, 2006 6:50 pm
Location: Moronfield....

Post by nottie »

If you connect air to it can you hear air coming out of the diff breather??
If so then perhaps the Oring is stuffed. Matbe as simple as a blocked air line.
Posts: 2492
Joined: Sun Nov 24, 2002 8:57 pm
Location: Melbourne

Post by bazzle »

Does the small ARB pump run up to pressure and stop.
Does it run again after operating the locker?

Bazzle
Posts: 2585
Joined: Fri Mar 28, 2008 4:45 pm
Location: SYDNEY

Post by thehanko »

bazzle wrote:Does the small ARB pump run up to pressure and stop.
Does it run again after operating the locker?

Bazzle
x2

maybe your shed compressor has enough flow to lock it up despite a leak whilst the little compressor has enough pressure but cant keep up with the leak.

if the little compressor keeps running after the initial pressure build up, or if you can hear air comming out your diff breather then its officially an air leaker and time to rip out the center.
*there's a rock, drive over it :) there's a bigger rock, drive over it :twisted: there's an even bigger rock, oops broke it :oops: Upgrade broken bit :bad-words:
Goto *
Posts: 80
Joined: Thu Oct 01, 2009 12:52 am
Location: SA

Post by VHPirie »

Got it working 2day. Used an old air compressor tank we had, chucked some fittings on it, the ARB pump, a tap, psi gauge, and an air release valve. Had to run a hose from the compressor in the shed to fill it up coz the arb pump took bloody ages lol.

But yeah went for a spin through heaps of mud/clay, and towed a mate through it behind in his VK Commo. On the way back the air ran out so the locker unlocked and it barely got back towing the car behind lol. Can't believe how much difference the locker makes!