One for the sparkies

Post by Shadow »

How do you wire up a 2 way switch?

I understand how the 2 way switching works, I am just unsure of the "best" way of implementing it.

The best way I can see of doing it is using SDI from each switch back to the light, a twin active between the two switches and have a supply feed to the back of the light. One of the SDI carries the active supply to the switches, the other SDI is hooked up to the light's active. This is exactly how i have done it for an irrigation pump before. But in this situation, the pump and supply were in the same location, which made using SDI to each switch the best solution anyway.

Is there a better way of doing it, ie, without the SDI links, and preferably by taking the supply down to the light switch (since its already there anyway)?

Oh, I realise this should all be done by a licenced electrician so no need to drum that into me.
Posts: 845
Joined: Sun Dec 17, 2006 8:28 pm
Location: Bairnsdale, East Gippsland

Post by jet-6 »

Correct, if you feed is alread at your light: You need a SDI to supply the feed to the 1st switch, then a twin between the two switches and the second SDI as the switch, it can run back with the twin or exit above the second switch

If your feed is at the switch: Very simple, switch or both switches hve feeds, add the twin between the two, and run a switch wire(RBE) from the best position, and feed the other common ternimal
Posts: 845
Joined: Sun Dec 17, 2006 8:28 pm
Location: Bairnsdale, East Gippsland

Post by jet-6 »

Also im assuming you know how to two way a switch?
Posts: 3064
Joined: Sun Jun 12, 2005 11:00 pm
Location: Yinnar South, Vic

Post by cloughy »

Or if from an existing switch you can run 3 strappers from the existing switch to the new one, negating the need to access the light ;)
Wanted: Car trailer or beaver tail truck, let me know what you got
Posts: 1175
Joined: Wed Jul 27, 2005 10:17 pm
Location: Mirboo North

Post by 6.5 rangie »

cloughy wrote:Or if from an existing switch you can run 3 strappers from the existing switch to the new one, negating the need to access the light ;)
yeah if its existing, then this would be the easiest option
Damien


--------------------------------------------------------
Posts: 5179
Joined: Fri Dec 05, 2003 8:15 pm
Location: Brisbane Australia

Post by Shadow »

jet-6 wrote:Also im assuming you know how to two way a switch?
Yep i understand the two poles etc.

So by your second option, when you say "feed the other common terminal" this means run an SDI from the switch not connected with the RBE, back to the other switch, which I then join to the active headed to the light?

ie, there are 3 actives running between the two switches?
Posts: 5179
Joined: Fri Dec 05, 2003 8:15 pm
Location: Brisbane Australia

Post by Shadow »

cloughy wrote:Or if from an existing switch you can run 3 strappers from the existing switch to the new one, negating the need to access the light ;)
ok, thats what i was thinking, 3 strappers means 3 sdi's? or a triple active?
Posts: 3064
Joined: Sun Jun 12, 2005 11:00 pm
Location: Yinnar South, Vic

Post by cloughy »

Shadow wrote:
cloughy wrote:Or if from an existing switch you can run 3 strappers from the existing switch to the new one, negating the need to access the light ;)
ok, thats what i was thinking, 3 strappers means 3 sdi's? or a triple active?
Or a twin an SDI :D ...Active in 1 and Switch wire in 2, or vice versa, strappers 1-1 C-C 2-2
Last edited by cloughy on Sun Jul 22, 2007 9:37 pm, edited 1 time in total.
Wanted: Car trailer or beaver tail truck, let me know what you got
Posts: 5179
Joined: Fri Dec 05, 2003 8:15 pm
Location: Brisbane Australia

Post by Shadow »

cloughy wrote:
Shadow wrote:
cloughy wrote:Or if from an existing switch you can run 3 strappers from the existing switch to the new one, negating the need to access the light ;)
ok, thats what i was thinking, 3 strappers means 3 sdi's? or a triple active?
Or a twin an SDI :D ...Active in 1 and Switch wire in 2, or vice versa, strappers 1-1 2-2 3-3
ok thats what i will do, i have an existing light, i want to loop another light off it, and then two way switch it at either end of the garage.
Posts: 845
Joined: Sun Dec 17, 2006 8:28 pm
Location: Bairnsdale, East Gippsland

Post by jet-6 »

The last option is the best for you, a twin and a sdi or 3 sdi's, its all the same!
Posts: 4073
Joined: Fri Apr 06, 2007 8:13 pm

Post by lump_a_charcoal »

But of course the licenced sparkie who does it for you will know the best way! :lol:

Once you get one light working, then loop off it... No need confusing the situation.
Posts: 2254
Joined: Tue Dec 10, 2002 5:09 pm
Location: Sydney

Re: One for the sparkies

Post by jessie928 »

Shadow wrote:How do you wire up a 2 way switch?

I understand how the 2 way switching works, I am just unsure of the "best" way of implementing it.

The best way I can see of doing it is using SDI from each switch back to the light, a twin active between the two switches and have a supply feed to the back of the light. One of the SDI carries the active supply to the switches, the other SDI is hooked up to the light's active. This is exactly how i have done it for an irrigation pump before. But in this situation, the pump and supply were in the same location, which made using SDI to each switch the best solution anyway.

Is there a better way of doing it, ie, without the SDI links, and preferably by taking the supply down to the light switch (since its already there anyway)?

Oh, I realise this should all be done by a licenced electrician so no need to drum that into me.

Image
ATTACH BROKEN TOYOTA HERE--->
DUCATI <-----Worlds best warning label
Posts: 5179
Joined: Fri Dec 05, 2003 8:15 pm
Location: Brisbane Australia

Re: One for the sparkies

Post by Shadow »

jessie928 wrote:
Shadow wrote:How do you wire up a 2 way switch?

I understand how the 2 way switching works, I am just unsure of the "best" way of implementing it.

The best way I can see of doing it is using SDI from each switch back to the light, a twin active between the two switches and have a supply feed to the back of the light. One of the SDI carries the active supply to the switches, the other SDI is hooked up to the light's active. This is exactly how i have done it for an irrigation pump before. But in this situation, the pump and supply were in the same location, which made using SDI to each switch the best solution anyway.

Is there a better way of doing it, ie, without the SDI links, and preferably by taking the supply down to the light switch (since its already there anyway)?

Oh, I realise this should all be done by a licenced electrician so no need to drum that into me.

Image
I googled that image myself, but when i read it, it appears to be a UK wiring standard, not AUS, ie, 2 wire supply etc.

I understood how the 3 way switching works, i was just unsure of how to effect the wiring to meet the australian standards.
Posts: 2254
Joined: Tue Dec 10, 2002 5:09 pm
Location: Sydney

Re: One for the sparkies

Post by jessie928 »

Shadow wrote:
jessie928 wrote:
Shadow wrote:How do you wire up a 2 way switch?

I understand how the 2 way switching works, I am just unsure of the "best" way of implementing it.

The best way I can see of doing it is using SDI from each switch back to the light, a twin active between the two switches and have a supply feed to the back of the light. One of the SDI carries the active supply to the switches, the other SDI is hooked up to the light's active. This is exactly how i have done it for an irrigation pump before. But in this situation, the pump and supply were in the same location, which made using SDI to each switch the best solution anyway.

Is there a better way of doing it, ie, without the SDI links, and preferably by taking the supply down to the light switch (since its already there anyway)?

Oh, I realise this should all be done by a licenced electrician so no need to drum that into me.

Image
I googled that image myself, but when i read it, it appears to be a UK wiring standard, not AUS, ie, 2 wire supply etc.

I understood how the 3 way switching works, i was just unsure of how to effect the wiring to meet the australian standards.
Image

teh third wire is simply ground. Its not switched. if you want just run it straight to your light socket. Alot of appliances do not use ground from the power point. and i think the standard changed recently so that even your lightbulb socket must have ground.


Jes
ATTACH BROKEN TOYOTA HERE--->
DUCATI <-----Worlds best warning label
Posts: 5179
Joined: Fri Dec 05, 2003 8:15 pm
Location: Brisbane Australia

Re: One for the sparkies

Post by Shadow »

jessie928 wrote:
Shadow wrote:
jessie928 wrote:
Shadow wrote:How do you wire up a 2 way switch?

I understand how the 2 way switching works, I am just unsure of the "best" way of implementing it.

The best way I can see of doing it is using SDI from each switch back to the light, a twin active between the two switches and have a supply feed to the back of the light. One of the SDI carries the active supply to the switches, the other SDI is hooked up to the light's active. This is exactly how i have done it for an irrigation pump before. But in this situation, the pump and supply were in the same location, which made using SDI to each switch the best solution anyway.

Is there a better way of doing it, ie, without the SDI links, and preferably by taking the supply down to the light switch (since its already there anyway)?

Oh, I realise this should all be done by a licenced electrician so no need to drum that into me.

Image
I googled that image myself, but when i read it, it appears to be a UK wiring standard, not AUS, ie, 2 wire supply etc.

I understood how the 3 way switching works, i was just unsure of how to effect the wiring to meet the australian standards.
Image

teh third wire is simply ground. Its not switched. if you want just run it straight to your light socket. Alot of appliances do not use ground from the power point. and i think the standard changed recently so that even your lightbulb socket must have ground.


Jes
standard changed in at least the 2000 update of the AS3000 (probably even 97) requiring twin+earth for lights.

Im quite familiar with electronics, being an electronic engineer and all >_<, just not so familiar with the finer points of mains electrical work.
Posts: 206
Joined: Tue Apr 12, 2005 1:59 pm
Location: Rockhampton QLD

Post by Pauwolf »

Dude
91 FJ 80 Project on the go - air lockers, 3in lift, super duper 3F, 36" pedes, toyota V8 getting prepped now
Posts: 3064
Joined: Sun Jun 12, 2005 11:00 pm
Location: Yinnar South, Vic

Post by cloughy »

Pauwolf wrote:Dude
OOOOOOOOOOOOOOkay :?
Wanted: Car trailer or beaver tail truck, let me know what you got
Posts: 5179
Joined: Fri Dec 05, 2003 8:15 pm
Location: Brisbane Australia

Post by Shadow »

i just ended up pulling 3 SDI's through

sparky's problem now when he comes to do the fitoff ^_^

built in a garage, didnt want sparky to come out to move 2 power points and add 3 runs of sdi, but he can come do the fitoff