Notice: We request that you don't just set up a new account at this time if you are a previous user.
If you used to be one of our moderators, please feel free to reach out to Chris via the facebook Outerlimits4x4 group and he will get you set back up with access should he need you.
Recovery:If you cannot access your old email address and don't remember your password, please click here to log a change of email address so you can do a password reset.

Isolating TD42

Tech Talk for Nissan owners.

Moderators: toaddog, V8Patrol

Post Reply
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Isolating TD42

Post by WHITEWIZARD »

Can anyone tell me how to isolate a TD42 properly and safely?
As at the moment i am only isolating the negatives and as it is a diesel it probably will still keep running under it's own compression (please correct me if i'm wrong)
Thanks
Follow The WHITEWIZARD!
Posts: 897
Joined: Tue Aug 02, 2005 2:31 am
Location: Central Coast

Post by MyGQ »

A Diesel will keep going if its got fuel, thats why there is a Fuel Cut Solinoid on the diesel pump that stops the pump getting fuel and stops the engine. This is pisitive activated and earthed through the injector pump to the motor. you need to isolate this to shut the engine down once its going. works on the same principal as a petrol motor, if you cut the power to the coil, the engine just stops
AA's for Quitters
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

So is it the fuel cut solinoid, is what cuts out when you turn the ignition off normally? or is it something different?
Follow The WHITEWIZARD!
Posts: 381
Joined: Sun Jan 23, 2005 2:56 pm
Location: singleton

Post by nayto »

some small diesels will use an air shutoff, usually as an emergency only but as MyGQ said easiest and safest is fuel shutoff solenoid
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

As i am not TD42 mechanically minded, is there any chance on info where this fuel solinoid is?
Follow The WHITEWIZARD!
Posts: 191
Joined: Thu Dec 07, 2006 8:56 pm
Location: Sunny Coast

Post by killer_garden_gnome »

if u isolate the negative the engine will still turn off, yes the pump is earthed to the motor but the motor is still earthed to the battery, if u isolate it ur are breaking the circuit
Posts: 381
Joined: Sun Jan 23, 2005 2:56 pm
Location: singleton

Post by nayto »

WHITEWIZARD wrote:As i am not TD42 mechanically minded, is there any chance on info where this fuel solinoid is?
its on the pump itself mate, iv got no photo but im sure someone on here will post 1 up for u.......
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

f u isolate the negative the engine will still turn off, yes the pump is earthed to the motor but the motor is still earthed to the battery, if u isolate it ur are breaking the circuit
Correct me if i'm wrong , but with diesels that can run under there own compression therefore still running the pump, this will still supply diesel still and keep running? I am confused as some will say the suggestion above and some will say solinoid. Can some one set me straight please as i don't really want to do it twice?

All and all thank you for your inputs :)
Follow The WHITEWIZARD!
Posts: 191
Joined: Thu Dec 07, 2006 8:56 pm
Location: Sunny Coast

Post by killer_garden_gnome »

if u isolate ur negative battery earth ur effectivly cutting all power to the car so in turn ur cutting power to the fuel solenoid so the motor can compress all it wants but it wont be getting fuel
Posts: 1836
Joined: Wed Aug 11, 2004 10:41 am
Location: Brisbane

Post by badger »

this would be true except the fuel cut solinoid is in the fuel line from the tank and therefore the pump may spin but no fuel will get thru and the motor will stop spinning very quickly once the fuel supply stops.

best bet if you wanna isolate a td42 is to put the switch in line with the wire from the ignition to the relay for the solinoid

if i could find a wireing diagram online atm id show u wich one
1hd-fte 5 speed tiptronic 105 series
78 series troopy for work
gu ute play truck For sale
FTE 80 series sahara Sold

i think i have a problem
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

OK, so what i have done already (isolating the negatives) is ok?
if u isolate ur negative battery earth ur effectivly cutting all power to the car so in turn ur cutting power to the fuel solenoid so the motor can compress all it wants but it wont be getting fuel
Thank you for your input, but as there is so much confusion on this topic and so many ideas you just don't know what's right. Thanks again and i will leave my set up as i got it, till someone says it's wrong.
Follow The WHITEWIZARD!
Posts: 191
Joined: Thu Dec 07, 2006 8:56 pm
Location: Sunny Coast

Post by killer_garden_gnome »

ifu have it already done cant u just try it?
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

this would be true except the fuel cut solinoid is in the fuel line from the tank and therefore the pump may spin but no fuel will get thru and the motor will stop spinning very quickly once the fuel supply stops.

best bet if you wanna isolate a td42 is to put the switch in line with the wire from the ignition to the relay for the solinoid

if i could find a wireing diagram online atm id show u wich one
Thanks badger, this does make sense too i will take this into account
Follow The WHITEWIZARD!
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

ifu have it already done cant u just try it?
It does sound stupid, but i just didn't know exactly what it would do, if i did loose fuel and IF it kept running it would run dry of diesel and i would have to re prime it (that's what i thought anyways) as mine had trouble last time re-priming and it is only for emergency too. I'm a little picky like that, I probably should try though
Follow The WHITEWIZARD!
Posts: 191
Joined: Thu Dec 07, 2006 8:56 pm
Location: Sunny Coast

Post by killer_garden_gnome »

i dont see why it will pump dry, as soon as u cut the power the fuel will cut and the motor will stop, it cant run on compressed air only, and if for some reason the circut to the pump is still complete it will simply keep running, but it wont
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

A Valid point.
Follow The WHITEWIZARD!
Posts: 4275
Joined: Thu Dec 19, 2002 2:12 pm
Location: Sydney

Post by ozy1 »

uponspeaking to an auto elec, i was advised not to put a kill switch on the negative, as this could damage diodes in the alternator, not sure on the alts in the gq but was advised against it,

on mine i run a continuous dudy solenoid on the positive of the battery, so once the solenoid is open nothing gets power, only thing left live in the truck is a small trigger wire
Posts: 1152
Joined: Mon Sep 25, 2006 8:25 pm
Location: the most livable planet in the universe

Post by its aford not a nissan »

the single wire going to the back of the injector pump controls the solinoid and this solinoid is what shuts the car off when you turn the key to off
so if you cut this wire no power will go to the solinoid therefor stopping any fuel from being pumped into the motor it wont run dry etc, as this is how you are supposed to stop the motor by shutting power off to the solinoid
anothe option is to use a big solinoid as suggested but for accessories only , i wouldnt run the starter through it or any heavy current drawing items
Posts: 4275
Joined: Thu Dec 19, 2002 2:12 pm
Location: Sydney

Post by ozy1 »

its aford not a nissan wrote:the single wire going to the back of the injector pump controls the solinoid and this solinoid is what shuts the car off when you turn the key to off
so if you cut this wire no power will go to the solinoid therefor stopping any fuel from being pumped into the motor it wont run dry etc, as this is how you are supposed to stop the motor by shutting power off to the solinoid
anothe option is to use a big solinoid as suggested but for accessories only , i wouldnt run the starter through it or any heavy current drawing items
the one i use is a continous duty 300Amp item, i run starter and all throught it, and have not had any dramas since fitting it back in march
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

Thanks for you input fellas at least it's pointed me in the right direction
Follow The WHITEWIZARD!
Posts: 404
Joined: Wed Apr 26, 2006 4:09 pm
Location: Pine Mountain

Post by MissGU »

Micheal
Call Aaron

He did mine & he'll tell you exactly what you need to do
Miss Lynda :P AKA Barbie :D
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

Thanks, I will call him
Follow The WHITEWIZARD!
Post Reply

Who is online

Users browsing this forum: No registered users and 48 guests