Isolating TD42
Isolating TD42
Can anyone tell me how to isolate a TD42 properly and safely?
As at the moment i am only isolating the negatives and as it is a diesel it probably will still keep running under it's own compression (please correct me if i'm wrong)
Thanks
As at the moment i am only isolating the negatives and as it is a diesel it probably will still keep running under it's own compression (please correct me if i'm wrong)
Thanks
Follow The WHITEWIZARD!
A Diesel will keep going if its got fuel, thats why there is a Fuel Cut Solinoid on the diesel pump that stops the pump getting fuel and stops the engine. This is pisitive activated and earthed through the injector pump to the motor. you need to isolate this to shut the engine down once its going. works on the same principal as a petrol motor, if you cut the power to the coil, the engine just stops
AA's for Quitters
Correct me if i'm wrong , but with diesels that can run under there own compression therefore still running the pump, this will still supply diesel still and keep running? I am confused as some will say the suggestion above and some will say solinoid. Can some one set me straight please as i don't really want to do it twice?f u isolate the negative the engine will still turn off, yes the pump is earthed to the motor but the motor is still earthed to the battery, if u isolate it ur are breaking the circuit
All and all thank you for your inputs
Follow The WHITEWIZARD!
this would be true except the fuel cut solinoid is in the fuel line from the tank and therefore the pump may spin but no fuel will get thru and the motor will stop spinning very quickly once the fuel supply stops.
best bet if you wanna isolate a td42 is to put the switch in line with the wire from the ignition to the relay for the solinoid
if i could find a wireing diagram online atm id show u wich one
best bet if you wanna isolate a td42 is to put the switch in line with the wire from the ignition to the relay for the solinoid
if i could find a wireing diagram online atm id show u wich one
1hd-fte 5 speed tiptronic 105 series
78 series troopy for work
gu ute play truck For sale
FTE 80 series sahara Sold
i think i have a problem
78 series troopy for work
gu ute play truck For sale
FTE 80 series sahara Sold
i think i have a problem
OK, so what i have done already (isolating the negatives) is ok?
Thank you for your input, but as there is so much confusion on this topic and so many ideas you just don't know what's right. Thanks again and i will leave my set up as i got it, till someone says it's wrong.if u isolate ur negative battery earth ur effectivly cutting all power to the car so in turn ur cutting power to the fuel solenoid so the motor can compress all it wants but it wont be getting fuel
Follow The WHITEWIZARD!
Thanks badger, this does make sense too i will take this into accountthis would be true except the fuel cut solinoid is in the fuel line from the tank and therefore the pump may spin but no fuel will get thru and the motor will stop spinning very quickly once the fuel supply stops.
best bet if you wanna isolate a td42 is to put the switch in line with the wire from the ignition to the relay for the solinoid
if i could find a wireing diagram online atm id show u wich one
Follow The WHITEWIZARD!
It does sound stupid, but i just didn't know exactly what it would do, if i did loose fuel and IF it kept running it would run dry of diesel and i would have to re prime it (that's what i thought anyways) as mine had trouble last time re-priming and it is only for emergency too. I'm a little picky like that, I probably should try thoughifu have it already done cant u just try it?
Follow The WHITEWIZARD!
uponspeaking to an auto elec, i was advised not to put a kill switch on the negative, as this could damage diodes in the alternator, not sure on the alts in the gq but was advised against it,
on mine i run a continuous dudy solenoid on the positive of the battery, so once the solenoid is open nothing gets power, only thing left live in the truck is a small trigger wire
on mine i run a continuous dudy solenoid on the positive of the battery, so once the solenoid is open nothing gets power, only thing left live in the truck is a small trigger wire
the single wire going to the back of the injector pump controls the solinoid and this solinoid is what shuts the car off when you turn the key to off
so if you cut this wire no power will go to the solinoid therefor stopping any fuel from being pumped into the motor it wont run dry etc, as this is how you are supposed to stop the motor by shutting power off to the solinoid
anothe option is to use a big solinoid as suggested but for accessories only , i wouldnt run the starter through it or any heavy current drawing items
so if you cut this wire no power will go to the solinoid therefor stopping any fuel from being pumped into the motor it wont run dry etc, as this is how you are supposed to stop the motor by shutting power off to the solinoid
anothe option is to use a big solinoid as suggested but for accessories only , i wouldnt run the starter through it or any heavy current drawing items
the one i use is a continous duty 300Amp item, i run starter and all throught it, and have not had any dramas since fitting it back in marchits aford not a nissan wrote:the single wire going to the back of the injector pump controls the solinoid and this solinoid is what shuts the car off when you turn the key to off
so if you cut this wire no power will go to the solinoid therefor stopping any fuel from being pumped into the motor it wont run dry etc, as this is how you are supposed to stop the motor by shutting power off to the solinoid
anothe option is to use a big solinoid as suggested but for accessories only , i wouldnt run the starter through it or any heavy current drawing items