Notice: We request that you don't just set up a new account at this time if you are a previous user.
If you used to be one of our moderators, please feel free to reach out to Chris via the facebook Outerlimits4x4 group and he will get you set back up with access should he need you.
Recovery:If you cannot access your old email address and don't remember your password, please click here to log a change of email address so you can do a password reset.

Internall cgae and A/C unit

Tech Talk for Nissan owners.

Moderators: toaddog, V8Patrol

Post Reply
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Internall cgae and A/C unit

Post by WHITEWIZARD »

Just got my internal cage done in my gu ute, and because where the tube comes done near the air conditioning unit fan, i can not fit it back in. Can you get smaller units so it can fit? or does it look like I may have to go with out? I would love to have it back in :D . Thanks
Follow The WHITEWIZARD!
Posts: 709
Joined: Thu Sep 22, 2005 7:49 pm
Location: campbelltown

Post by Mousie »

ask thunder... he has a internal cage in his GU .. i am shore he has his ac still working!...
R.A.G, Ruff As Gutts 4x4 club :P
http://www.rag4x4.com/
Posts: 3739
Joined: Sat Dec 11, 2004 10:10 pm

Post by mickyd555 »

Shane has his AC working and still has his cage. You also need to have that fan unit running for the windscreen demister.

Bring it round and show it to me
Posts: 14
Joined: Tue Apr 18, 2006 7:12 pm

Post by ruffgu »

i have a 8 point Brown davis internal cage in a gu wagon and the front legs go down towards the front of the dash but i havent lost any of the a/c dusts just the the drivers side vent cant move from side to side.
Posts: 1857
Joined: Fri Feb 02, 2007 12:16 am
Location: ipswich

Post by nastytroll »

trollism has a cage n still has all his a/c
Posts: 1095
Joined: Sat Nov 30, 2002 7:53 am
Location: SYDNEY

Post by thunder »

as my cage is engineered,the bar could not go down near the door.It had to be down the dash and thru the blower box.I pm'd whitewizard
also to pass engineer the blower box had to work

put a smaller fan in it and tapped the crap out of the box where we cut abour 35% out of it.it works but not as good as new.

its been like that for 3yrs and not a problem!
Bar work RDG
www.rdgengineering.com
ADRENALIN TRANSPORT
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

What sort of smaller unit did you get? and where from? Thanks
Follow The WHITEWIZARD!
Posts: 1095
Joined: Sat Nov 30, 2002 7:53 am
Location: SYDNEY

Post by thunder »

a mate went to a workshop that had some,,they said help yourself.it was free

1st one didnt fit,,too big 2nd did

im guessing its from a hatch or small car
Bar work RDG
www.rdgengineering.com
ADRENALIN TRANSPORT
Posts: 138
Joined: Thu Aug 26, 2004 5:10 pm
Location: Brisy

Post by WHITEWIZARD »

ok, thanks for your help, i'll give it a go.
Follow The WHITEWIZARD!
Post Reply

Who is online

Users browsing this forum: No registered users and 7 guests