hilux 7mge getting hot

Post by 302 cruiser »

i was just wondering if anyone on here has done this conversion and what they did for fans i have 2, 10 inch thermos in front of the rad, but it still gets a bit worm pulling up hills. i am not sure if the trouble is the fans or the the rad it could bea bit blocked i not sure
Posts: 75
Joined: Tue May 23, 2006 1:19 pm
Location: brisbane

Post by evo wagon »

they are know for poping head gaskets all the time so i'd check that other wise i'd get the rad out and flushed if its only doing it under load then thats where i'd start. stick a new thermostat in as well. what brand fans are you using?
Posts: 184
Joined: Mon May 21, 2007 10:15 am
Location: floatin around

Post by 302 cruiser »

head gasket just replaced new thermostat installed not sure on brand of fans my refridgeration mechanic mate got them from heatcraft or somewere like that
Posts: 549
Joined: Sat Jul 23, 2005 5:33 pm
Location: Sunshine Coast

Post by Frankenyota »

What sort of radaitor are you running?
A 3 core diesel is recommended.

Matt
Posts: 75
Joined: Tue May 23, 2006 1:19 pm
Location: brisbane

Post by evo wagon »

well i'd get the rad checked out than and was the water pump replaced possible problem with the impella. if you still have problems try getting some themo fans named sonic they are great.
Posts: 184
Joined: Mon May 21, 2007 10:15 am
Location: floatin around

Post by 302 cruiser »

you should know matt i bought it from you
Posts: 184
Joined: Mon May 21, 2007 10:15 am
Location: floatin around

Post by 302 cruiser »

i am thinking about running a 16 inch fan instead of the 2 10s i think it is just an air flow problem
Posts: 3349
Joined: Tue Nov 23, 2004 10:29 am
Location: Not where you are

Post by Gribble »

302 cruiser wrote:i am thinking about running a 16 inch fan instead of the 2 10s i think it is just an air flow problem
Forget the fans, they really only work under 40kmh, which in a 4wd would be crawling. What radiator are you running?
\m/
Posts: 1208
Joined: Fri Nov 08, 2002 8:21 pm
Location: sunshine coast

Post by killalux »

i had slight issues with the 7MGTE getting hot when worked hard, and i think it all comes down to a lack of cooling ability by the radiator. ie not big enough. I suspect if you bought the conversion from matt then you have my old radiator (i sold it to matt), which is a 3 core diesel.

I would try maybe a bonnet scoop to help get a bit more airflow through the engine bay.
Just before my 7MGTE blew, it was getting really hot offroad, so i pulled the bonnet off, and it made a big difference, i was in a 4WD park though, don't suggest you do this on road
KILLA KUSTOM KABLES
CUSTOM AUTO ELECTRICAL SPECIALISTS
0404811498
LS1 & DURAMAX ENGINE CONVERSIONS, DRIVE IN DRIVE OUT. PATROLS AND CRUISERS

LS1 STANDALONE HARNESS $475ex
Posts: 549
Joined: Sat Jul 23, 2005 5:33 pm
Location: Sunshine Coast

Post by Frankenyota »

Hey Trent wasn't sure which radiator you were running.

Never used the diesel one, so maybe steve will know if it needs a clean out?
Wouldn't hurt to get it checked.

On my V6 i have dual 11" fans, high output, which seem to be fine.
Car sits on 95 on the road but will heat up when driven harder.

The fans worked much better when i put a shroud on.
Also went to a lower temp thermostat which helped.
Are your fans pullers or pushers?

Matt
Posts: 184
Joined: Mon May 21, 2007 10:15 am
Location: floatin around

Post by 302 cruiser »

killalux so you are to blame for the clutch setup. it didnt work real well at all i changed throwout bearings put origanal push rod back in slave cylinder and modded clutch fork so slave cylinder could be mounted on bell housing propely and push on clutch fork closer to bell housing so it would disengage properly. did it disengage for you did you change something at master cylinder end. what fans were you running on your 7mgte

matt my fans are pushers in front of the rad
Posts: 2097
Joined: Tue Aug 12, 2003 6:50 pm
Location: wollongong

Post by dow50r »

One way to check if it is a radiator problem is to turn up the heater flat out....if the gauge drops temperature, you have a radiator problem, if it makes bugger all difference, you may have a fuel pump problem, which makes the motor run lean....take off the fuel return to tank and put a hose there into a bucket....see that there is always a descent flow returning...if you rev it and the flow stops, you have lean mixture that will cause excess heat....this is especially prevalent in non efi fuel tanks with external pumps....get a efi tank in there is the best option.
Andrew
Confucious say...man who argue with idiot, worserer himself
Posts: 1208
Joined: Fri Nov 08, 2002 8:21 pm
Location: sunshine coast

Post by killalux »

302 cruiser wrote:killalux so you are to blame for the clutch setup. it didnt work real well at all i changed throwout bearings put origanal push rod back in slave cylinder and modded clutch fork so slave cylinder could be mounted on bell housing propely and push on clutch fork closer to bell housing so it would disengage properly. did it disengage for you did you change something at master cylinder end. what fans were you running on your 7mgte

matt my fans are pushers in front of the rad
Clutch worked fine for me, never had a problem???

i had 2 11" fans, in front of rad. I think 2 10's would work better anyway, cause with the 11's they didn't sit hard against the rad so air would escape betwwen the fan and rad.
KILLA KUSTOM KABLES
CUSTOM AUTO ELECTRICAL SPECIALISTS
0404811498
LS1 & DURAMAX ENGINE CONVERSIONS, DRIVE IN DRIVE OUT. PATROLS AND CRUISERS

LS1 STANDALONE HARNESS $475ex
Posts: 1208
Joined: Fri Nov 08, 2002 8:21 pm
Location: sunshine coast

Post by killalux »

radiator was flushed when they modified the outlets
KILLA KUSTOM KABLES
CUSTOM AUTO ELECTRICAL SPECIALISTS
0404811498
LS1 & DURAMAX ENGINE CONVERSIONS, DRIVE IN DRIVE OUT. PATROLS AND CRUISERS

LS1 STANDALONE HARNESS $475ex
Posts: 184
Joined: Mon May 21, 2007 10:15 am
Location: floatin around

Post by 302 cruiser »

dow50r i am about to put a bigger outlet into my tank not because of the heat problem but because i thought it would be a good idea but i will see how it goes after i do it