radiator under tray... will i need a eletric watter pump?

Post by jonno_racing »

just looking at where to put my radiator, if i run it under the tray, will i need a eletric water pump to go with the mechanical one???

the motor is 100kw 4age and the radiator is of a EL falcon
Posts: 3132
Joined: Wed Sep 28, 2005 3:22 pm
Location: Newy

Post by HotFourOk »

Yeah, I'm fairly sure you'd need one inline to assist flow to the back of the car, and through the radiator and back again.
[quote="RockyF70 - Coming out of the closet"]i'd be rushing out and buying an IFS rocky[/quote]
Posts: 4825
Joined: Sun May 04, 2003 6:33 pm
Location: Berwick vic

Post by droopypete »

While I am no expert (and I hate people guessing the answer to others questions just to boost their post count) I would think there may be conflicting flow rates with miss matched pumps.
if pump #1 flows 100 litres per minute and pump #2 only flows 50, in a sealed cooling system that has to be a problem.
Peter.
Cable bracing is the way of the future!

v840 said "That sounds like a booty fab, hack job piece of shit no offence."
Posts: 578
Joined: Fri Feb 15, 2008 9:07 am
Location: st hellens

Post by jonno_racing »

thats true..
i was putting some thought into takeing the fins off the standard pump and just reling on the eletric.. but not all that keen on that idea!
Posts: 152
Joined: Wed Feb 27, 2008 12:28 pm
Location: Here, there, everywhere!

Post by tt6_lux »

Drill a few 4mm holes in the thermostat, this will prevent the electric pump from cavitating. Also, with moving the radiator to the rear you may have issues with purging all the air out of the system, look at where your high points are and consider adding bleeder lines to a higher point.
Posts: 3278
Joined: Mon Mar 03, 2003 9:03 pm
Location: St Helena, Melbourne.

Post by Loanrangie »

The davies craig electric pumps are excellent, my old man has one on his 1927 dodge to replace the engine driven pump due to fitiing a later engine to it, at cruise it doesnt need to run at all.
Saddle up tonto, its the not so loanrangie! . 98 TDI DISCO lightly modded with more to come.
Posts: 3385
Joined: Fri Sep 17, 2004 8:26 pm
Location: Melbourne

Post by shakes »

jonno_racing wrote:thats true..
i was putting some thought into takeing the fins off the standard pump and just reling on the eletric.. but not all that keen on that idea!
just rely on the elctric, the 4age opens up that much more without the factory water pump it's insane
Posts: 7230
Joined: Mon Oct 21, 2002 10:42 pm
Location: Brisbane

Post by MissDrew »

I only run the standard water pump on my 1uz and I run a rear mounted rad, have no problems at all with it.
Posts: 3443
Joined: Tue Oct 29, 2002 10:50 pm
Location: Currently On the Road !!

Post by Dozoor »

I ran a v6 com with a rear mount RR radiator with the standard pump
no probs -- as stated by tt6 removing all air from the system is more the issue.
Posts: 1170
Joined: Tue Jun 01, 2004 4:27 pm
Location: Goodna, Queensland

Post by Bartso »

same as well i have radiator in the rear using standard water pump from VN 5.0L and works fine but as stated make sure all the air is out or you'll have issues ;)
MUD BEERS & MAYHEM 4x4 & SOCIAL Group
[url=http://www.fourbys.com.au/]Fourby's tyre and mechanical[/url]
[url=http://www.4wdmonthly.com.au/forum/showthread.php?t=24441/]My build up for ttc[/url]
Posts: 7230
Joined: Mon Oct 21, 2002 10:42 pm
Location: Brisbane

Post by MissDrew »

As long as you run the lines correctly and have them like U and not a W (I`m talking as if you took a side cross section of you rig and pipes) its easy to get all the air out if you have a bleed point at the 2 highest points in the system.
If you have no choice but to have a W effect then have a 3rd bleed point at the other high point.