few 80 series questions

Post by 4runnernomore »

Hi all,

Have a few queries:

Fitting of GXL rear seats in to a Standard (middle row)?

Are the petrol 4.5 and 1hz fan shrouds the same?

4.5 litre and 1hz water temp sensors the same?

91 1hz subtank soonoid, is a blue marlin petrol one compatabile (unsure of year)?

Cheers, Chris
Posts: 522
Joined: Sat Jan 29, 2005 7:40 am
Location: Melbourne, Vic

Re: few 80 series questions

Post by Toy80Diesel »

4runnernomore wrote:Hi all,

Have a few queries:

Fitting of GXL rear seats in to a Standard (middle row)?

Are the petrol 4.5 and 1hz fan shrouds the same?

4.5 litre and 1hz water temp sensors the same?

91 1hz subtank soonoid, is a blue marlin petrol one compatabile (unsure of year)?

Cheers, Chris
Chris,
The rear seats attach to the car with a steel bracket over the wheel arch so I don't think you can make them work in the centre of the vehicle. You would also need the locking points in the floor to lock them down.

Radiator is the same, but I'm not 100% on the shroud.

In a Diesel, you use the two tanks seperately, in a petrol it pumps the fuel from the sub into the main. So it's a different system as one activates a pump and the other activates the splitter to get fuel from which tank you select.

Hope this helps.
Shut Up, Get Out, & Start Digging...
Posts: 79
Joined: Tue Jun 19, 2007 9:52 pm
Location: Darwin

Post by 4runnernomore »

Thanks for that Toy80Diesel .

I have got the good oil on the seats and they will fit without major hassles or mods.

Fingers crossed on the shroud.

Cheers, Chris
Posts: 79
Joined: Tue Jun 19, 2007 9:52 pm
Location: Darwin

Post by 4runnernomore »

No good on the shroud. It was different.
Posts: 345
Joined: Mon Aug 04, 2008 8:48 am

Post by chpd80 »

The deisel uses the sub tank by draining it into the main tank, you cannot select to use the sub tank, you can only start filling it when the main tank gets down below half.
Posts: 3740
Joined: Sat May 26, 2007 5:04 pm
Location: Licking a window near you

Post by 80's_delirious »

chpd80 wrote:The deisel uses the sub tank by draining it into the main tank, you cannot select to use the sub tank, you can only start filling it when the main tank gets down below half.
um, no. dont think so. The diesels 80 series use solinoid valves. When you hit the sub tank switch the vlves close the main tank outlet and return hose and open the sub tank outlet and return hoses. The two tanks are independent.
Petrol 80s have a transfer pump in the sub tank, this pumps fuel from sub tank into main.
Posts: 345
Joined: Mon Aug 04, 2008 8:48 am

Post by chpd80 »

Um no, the 80 series 1hz DIESEL I owned filled the sub tank into the main tank as the petrol does, it even states this in the owners manual and the service book that it does this,
and tells you to make sure the main tank is down to 1/4 before filling it from the sub tank, in which time you will see the sub tank gauge go down and the main tank go up.
Posts: 284
Joined: Fri Mar 12, 2004 3:43 pm
Location: Rockhampton

Post by skootin »

Then why is there a three way soleniod on the return line?
Maybe it returns the fuel to the same tank it was taken from.
I'm not stuck I'm over here!
Watch where you driven!!!
Posts: 345
Joined: Mon Aug 04, 2008 8:48 am

Post by chpd80 »

dont know skootin,??? just stating what mine did and what the gregory's manual etc stated.
Maybe toyota made both systems, hey???
Posts: 734
Joined: Sun Mar 06, 2005 5:25 pm
Location: Sunshine Coast Queensland

Post by midi73 »

chpd80 wrote:Um no, the 80 series 1hz DIESEL I owned filled the sub tank into the main tank as the petrol does, it even states this in the owners manual and the service book that it does this,
and tells you to make sure the main tank is down to 1/4 before filling it from the sub tank, in which time you will see the sub tank gauge go down and the main tank go up.
Uuumm, well my turbo diesl 80, draws from each tank individually. I switch the switch and use whatever tank I want to. I know it does, I just did it to see what ks I can get out of each tank. Maybe tubo and non turbo are different.
Posts: 624
Joined: Mon Aug 21, 2006 8:40 pm
Location: Albany, WA

Post by Kitika »

My 1990 1hz draws from both tanks separately. The petrol models only pump fuel from the subtank to the main because the main tank has the high pressure pump to supply the efi motor. The diesels suck the fuel from what ever tank the solenoid has selected.
Then why is there a three way soleniod on the return line?
Maybe it returns the fuel to the same tank it was taken from.
Yes it returns it to the tank that is selected so you don't drain it dry and have to keep swapping between tanks.
More Suzuki parts going to the big Suzuki Heaven in the sky!
Posts: 345
Joined: Mon Aug 04, 2008 8:48 am

Post by chpd80 »

Fairnugh I stand corrected, :D :D