Notice: We request that you don't just set up a new account at this time if you are a previous user.
If you used to be one of our moderators, please feel free to reach out to Chris via the facebook Outerlimits4x4 group and he will get you set back up with access should he need you.
If you used to be one of our moderators, please feel free to reach out to Chris via the facebook Outerlimits4x4 group and he will get you set back up with access should he need you.
Recovery:If you cannot access your old email address and don't remember your password, please click here to log a change of email address so you can do a password reset.
Fuel System
Moderators: toaddog, TWISTY, V8Patrol, Moderators
Fuel System
i've posted this in the zuk section, but its more of a general question
at the moment i'm setting up my fuel system. i've got a fuel cell, a lifter pump, surge tank, external vl commodore pump and a heap of hose to join up. i've done a diagram below of how i'm thinking of doin it all, take a look and see if theres something i should change
the only thing i'm worried about is the lifter pump, its specs are 4-7psi and 132 litres per minute. sound about right for a lifter pump to feed a surge tank?
at the moment i'm setting up my fuel system. i've got a fuel cell, a lifter pump, surge tank, external vl commodore pump and a heap of hose to join up. i've done a diagram below of how i'm thinking of doin it all, take a look and see if theres something i should change
the only thing i'm worried about is the lifter pump, its specs are 4-7psi and 132 litres per minute. sound about right for a lifter pump to feed a surge tank?
You do not have the required permissions to view the files attached to this post.
zooki suggested moving the return from the engine to the tank, instead of the surge tank but problem is, the cell only has three holes, two in the sump, and one at the top. will it cause drama's if i run the surge return to the hole alongside the outlet in the sump? and then have the engine return come back into the top of the cell??? 
In one of my books it says both options are pretty viable in regards to the return line. The preffered method is to do a return straight to the fuel tank provided the lifter pump can keep up with the engines demand for fuel. If you take the return line to the surge tank you have the possibility of heating up the fuel (as its cirulating around the engine fuel lines) which is bad for performance.
I wouldn't say that putting the return to the base of the main tank is such a bad thing. I see the only neative as it may stir up all the silt and sh*t thats settled at the bottom of the cell. If this is a comp machine would you be cleaning out the tank regularly or what? Wouldn't be to dificult to get another hole tapped into the top or side of the cell.
edit* just read the thread in the zook section and they've said pretty much the same thing
I wouldn't say that putting the return to the base of the main tank is such a bad thing. I see the only neative as it may stir up all the silt and sh*t thats settled at the bottom of the cell. If this is a comp machine would you be cleaning out the tank regularly or what? Wouldn't be to dificult to get another hole tapped into the top or side of the cell.
edit* just read the thread in the zook section and they've said pretty much the same thing
-Scott- wrote:Isn't it a bit early in the day to be pissed?
Re: Fuel System
antt thats how i done the fuel system in trev and i have'nt had any probs yet but if heat is a factor where the tank is run the line back to the main tankantt wrote:i've posted this in the zuk section, but its more of a general question
at the moment i'm setting up my fuel system. i've got a fuel cell, a lifter pump, surge tank, external vl commodore pump and a heap of hose to join up. i've done a diagram below of how i'm thinking of doin it all, take a look and see if theres something i should change
the only thing i'm worried about is the lifter pump, its specs are 4-7psi and 132 litres per minute. sound about right for a lifter pump to feed a surge tank?
not sure on the line size, its a touch bigger than standard zuk stuff cause i couldn't get a reducer that'd fit the cell and the standard hose size.
not sure on pump brand either, they're not holley's or anything, just something from Thompsons. the main pump is a vl commodore one, and the lifter pump has the specs i said above (4-7psi, and 132 litres per minute)
not sure on pump brand either, they're not holley's or anything, just something from Thompsons. the main pump is a vl commodore one, and the lifter pump has the specs i said above (4-7psi, and 132 litres per minute)
Everything looks fine to me except for where you have the filter. I know in your mind you say put the filter before the pump and in a carb system this is fine because generaly you only run 3-5PSI fuel press. But with an EFI System they run around 32PSI constant and supply to the pump is very important so any restriction to the pump can cause the pump to fail premiturly. Also the Fuel on an EFI system can be returned to the Surge can eficiantly because although the fuel has allready been to the engine it doesnt get real hot. Fuel flows pretty fast through the fuel rail at 32PSI so doesnt get much heat soak.
From the specs on your lift pump and the amount of fuel a 1.6 will consume i doubt you will run the surge can out of fuel.
From the specs on your lift pump and the amount of fuel a 1.6 will consume i doubt you will run the surge can out of fuel.
a
i use'd a holley blue pump for the push pump 15psi and a vl pump as well for the high pressure . the setup u have should work greatantt wrote:not sure on the line size, its a touch bigger than standard zuk stuff cause i couldn't get a reducer that'd fit the cell and the standard hose size.
not sure on pump brand either, they're not holley's or anything, just something from Thompsons. the main pump is a vl commodore one, and the lifter pump has the specs i said above (4-7psi, and 132 litres per minute)
i didn't think off the fuel filter in that positoin tony. in mine the filter is after the h/pump . good callRUFF wrote:Everything looks fine to me except for where you have the filter. I know in your mind you say put the filter before the pump and in a carb system this is fine because generaly you only run 3-5PSI fuel press. But with an EFI System they run around 32PSI constant and supply to the pump is very important so any restriction to the pump can cause the pump to fail premiturly. Also the Fuel on an EFI system can be returned to the Surge can eficiantly because although the fuel has allready been to the engine it doesnt get real hot. Fuel flows pretty fast through the fuel rail at 32PSI so doesnt get much heat soak.
From the specs on your lift pump and the amount of fuel a 1.6 will consume i doubt you will run the surge can out of fuel.
I'm really just going off what the book says (it is performance based). Basically the hotter fuel can lead to early detonation. It really depends on how stressed the motor is I suppose, if it takes it easy then I guess heat soak may not be a problem but if your revin the crap out of it you might notice it gets hotter quicker and detonation may become a problem. It goes on to say the bigger the surge tank, the less important the issue becomes (more fuel, longer it takes to heat up, bigger tank disapates heat quicker etc.).antt wrote:does the heated fuel cause 'that' much of a problem? i mean its a 1.6 litre suzuki motor, not really a performance motor. i cant really easily put a new return inlet in the fuel tank, as its a plastic fuel cell
Just looking at your lifter pump specs and I rekon 132l/min is gonna be plenty (f'ing huge actually - is it a holley carb pump or something or just a generic lifter pump?). According to this book the vl pump only flows 2.8l/min with no restriction anyway (2.3l/min@36-40psi). You might even find with that sort of flow with the lifter pump that the fuel cycles with the main fuel cell enough that heat soak does not become an issue.
edit* 5 replys already while I typed this. I'm way behind the 8 ball tonight.
Last edited by stuee on Wed Mar 22, 2006 9:19 pm, edited 1 time in total.
-Scott- wrote:Isn't it a bit early in the day to be pissed?
Thats 2.2l/min. In that case its probably a safer bet to return to the surge tank. After what RUFF said heat probably dwon't be an issue nd you risk staring the vl pump if ou thrash it for an extended period of time(2.3l/min vs 2.2l/min)antt wrote:now that i think about it, pretty sure it was litres per hour
edit: surge tank is 2 litre capacity
-Scott- wrote:Isn't it a bit early in the day to be pissed?
thanks for the tip rhett, the cell (jaz brand) has foam in it
i've found something on ebay that i'm pretty sure has similar specs to the lifter pump i'm got
http://cgi.ebay.com/12V-UNIVERSAL-ELECT ... dZViewItem
i've found something on ebay that i'm pretty sure has similar specs to the lifter pump i'm got
http://cgi.ebay.com/12V-UNIVERSAL-ELECT ... dZViewItem
i am going to run a big surge tank like 3 litres and return into the surge tank to ensure the tank always has fuel so on a steep climb you can get to the top without dramas. v8 supercars run an 8 litre surge tank returning into the surge tank thus having 2 laps warning about fuel refueling when the main tank is empty.
cheers bru
cheers bru
ADHD Racing would like to thank
Mrs Bru @ Sunshine Coast Developmental Physiotherapy - www.scdphysio.com.au , Ryano @ Fourbys www.generaltire.com.au Blitzkrieg Motorsport
Mrs Bru @ Sunshine Coast Developmental Physiotherapy - www.scdphysio.com.au , Ryano @ Fourbys www.generaltire.com.au Blitzkrieg Motorsport
Who is online
Users browsing this forum: No registered users and 4 guests