OBA question

Post by 360 scout »

g'day just plumbing up a electric air compressor & old fire extinguish for a tank just wondering when the whole system is pressurised will the air leak back past the piston seals on the comp. or do i have to fit a one way valve.
what do the arb's have on their compressors used with the lockers is the compressor cylinder pressurised all the time?? :?:
The compressor's a chassis tech DC5000 supposed to be rated at 3.6cfm & 130 psi used on air suspensions/bags.

cheers Andrew
TOYOTAS ARE LIKE TAMPONS!! every pussie has one!


Nitrous is like a hot chick with an STD...You know you want to hit it...Your just afraid of the consequences
Posts: 2031
Joined: Tue Oct 22, 2002 10:49 am
Location: On a mission...

Re: OBA question

Post by Damo »

360 scout wrote:g'day just plumbing up a electric air compressor & old fire extinguish for a tank just wondering when the whole system is pressurised will the air leak back past the piston seals on the comp. or do i have to fit a one way valve.
what do the arb's have on their compressors used with the lockers is the compressor cylinder pressurised all the time?? :?:
The compressor's a chassis tech DC5000 supposed to be rated at 3.6cfm & 130 psi used on air suspensions/bags.

cheers Andrew
I think it would depend on the compressor. Any OBA setups I have seen detailed have put a check valve in after the compressor. Do you know what a check valve would cost you? I dunno, but I can't see them being that expensive. I'd be inclined to put one in.
Posts: 2492
Joined: Sun Nov 24, 2002 8:57 pm
Location: Melbourne

Post by bazzle »

Fit high temp syn rubber line to compressor. At tank end use a one way valve away from the heat. ARB comp stays pressurised. Uses valve in cyl head.

Bazzle
Posts: 2809
Joined: Mon Jan 02, 2006 5:03 pm
Location: Lara Victoria

Post by Ruffy »

I used a gas lock off valve that is powered by the compressor power wire.
[quote="Uhhohh"]As far as an indecent proposal goes, I'd accept nothing less than $100,000 to tolerate buggery. Any less and it's just not worth the psychological trauma. [/quote]
Posts: 236
Joined: Thu Apr 27, 2006 9:40 pm
Location: Gippsland, Vic

Post by currentlyoffline »

Ruffy wrote:I used a gas lock off valve that is powered by the compressor power wire.
Awesome idea, but what do they cost ?
Posts: 69
Joined: Mon May 29, 2006 1:05 pm
Location: dandenong ranges melbourne

Post by gqtrol »

i would be thinking about installing a pressure relief valve to that as well buddy you don't wont to blow any thing up that could cause catastrophic damage.look into it properly before you start fiddling around with compressed air especialy when your talking about a couple of hundred psi just my thoughts
GQTROL
Posts: 5803
Joined: Wed Feb 19, 2003 3:02 pm
Location: Brisbane

Post by ISUZUROVER »

In my system I have a metal one-way valve immediately after the compressor (valve is from the vacuum line of an old bluebird - $1 from a wrecker - most old jap cars have metal valves newer plastic - which is no good).

On the tank I have an adjustable safety valve - about $5 from tradetools. I also have an electrical pressure cutoff switch (same as used on an industrial compressor) - about $30 from tradetools.
_____________________________________________________________
RUFF wrote:Beally STFU Your becoming a real PITA.
Posts: 96
Joined: Fri Nov 26, 2004 3:57 pm
Location: North of Clermont Qld

Post by 360 scout »

Ruffy wrote:I used a gas lock off valve that is powered by the compressor power wire.
yeh Iwas thinking about the same thing got a spare left over from my dual fuel set up .
was thinking the compressor might be air tight while it's new but prob start leaking later on. :twisted:
TOYOTAS ARE LIKE TAMPONS!! every pussie has one!


Nitrous is like a hot chick with an STD...You know you want to hit it...Your just afraid of the consequences
Posts: 5803
Joined: Wed Feb 19, 2003 3:02 pm
Location: Brisbane

Post by ISUZUROVER »

360 scout wrote:
Ruffy wrote:I used a gas lock off valve that is powered by the compressor power wire.
yeh Iwas thinking about the same thing got a spare left over from my dual fuel set up .
was thinking the compressor might be air tight while it's new but prob start leaking later on. :twisted:
No - the compressors are never 100% tight - but the main problem is that you have high pressure on one side and atmospheric pressure on the other, so you can spin them backwards when shut off (without a one-way valve).