Notice: We request that you don't just set up a new account at this time if you are a previous user.
If you used to be one of our moderators, please feel free to reach out to Chris via the facebook Outerlimits4x4 group and he will get you set back up with access should he need you.
Recovery:If you cannot access your old email address and don't remember your password, please click here to log a change of email address so you can do a password reset.

arb locker pressures

General Tech Talk

Moderators: toaddog, TWISTY, V8Patrol, Moderators

Post Reply
Posts: 615
Joined: Tue Feb 11, 2003 4:59 pm
Location: Geelong Vic

arb locker pressures

Post by Ruggers »

i was wondering if any body know what pressure arb lockers run at. i an getting a rear locker but if i can hook it up to my onboard air when i bolt that back on would be good. im going to run a t piece with un pressurised air for tyres and tools and regulate presure for the lockers. do you guy reckon this will be ok or should i get the arb compressor. thanks chris
Posts: 16934
Joined: Sun Oct 20, 2002 6:57 pm

Post by RUFF »

OBE will be fine. A small storage tank would be worth it as well.
ARB recomend 90psi to operate their lockers.
Posts: 1208
Joined: Fri Nov 08, 2002 8:21 pm
Location: sunshine coast

Post by killalux »

i read somewhere in the air lock manual that they cant take over 105 PSI
Posts: 615
Joined: Tue Feb 11, 2003 4:59 pm
Location: Geelong Vic

Post by Ruggers »

killalux wrote:i read somewhere in the air lock manual that they cant take over 105 PSI


thats good to know i was planning on running 120psi so i wont have to get a special regulator for it. save me some money to
Posts: 2832
Joined: Sat Oct 26, 2002 3:15 pm
Location: Ringwood East, VIC

Post by RoldIT »

killalux wrote:i read somewhere in the air lock manual that they cant take over 105 PSI


120psi prob won't be very good ...
KRiS
Posts: 714
Joined: Sun Aug 17, 2003 8:58 pm
Location: Cairns, (capital of Nth QLD)

Post by Kev80 »

I was told by ARB that they run at 90psi but the seals can blow out at 110psi so id be carefull or seek more advice.

Also i suggest fitting a over pressure release valve (adjustable) as my ARB pressure switch failed in the closed contact possition resulting in the compressor constantly running and blowing my front diff lock seal. :bad-words:

A $10 valve is cheap insurance !
Last edited by Kev80 on Mon Aug 25, 2003 2:42 pm, edited 1 time in total.
GXL Turbo Diesel 80 series- 6" King springs + Rancho in-cab kit- 35" BFG Muds Twin ARB airlockers.
Posts: 407
Joined: Wed Aug 20, 2003 10:02 am
Location: Hornsby Sydney

Post by Surfin Alec »

The pressure switch on my old ARB air compressor for the locker was a 75psi switch.
GO the 80...The mods have started :-)
Posts: 714
Joined: Sun Aug 17, 2003 8:58 pm
Location: Cairns, (capital of Nth QLD)

Post by Kev80 »

It probebly switches on at 75psi and cuts out at 90psi.
GXL Turbo Diesel 80 series- 6" King springs + Rancho in-cab kit- 35" BFG Muds Twin ARB airlockers.
Posts: 1208
Joined: Fri Nov 08, 2002 8:21 pm
Location: sunshine coast

Post by killalux »

the arb pressure switch i run on my airtank cuts out at 110 psi and in at about 80
Posts: 615
Joined: Tue Feb 11, 2003 4:59 pm
Location: Geelong Vic

Post by Ruggers »

thanks im going to run two line from my tank one unrestricted for air tools/tyres and one with a pressure reg and blow off valve set at around 100 to 105. to blow off. should go alright when i get it going. just one more question i have a sanden with teh oil sump. should i tap it to put a grease nipple in or put an inline oiler and oil separtor in or just top it with oil and regularly check it before trips. thanks chris
Posts: 2739
Joined: Sat Oct 26, 2002 7:50 am
Location: Melbourne

Post by Bitsamissin »

Yes I fitted a pressure gauge to the ARB compressor and it comes on at 75psi and cuts out at 90psi.
It would not take much more than 90psi to blow the O ring seal out.
I just luv my "clacker Jabber"
Posts: 3523
Joined: Sun May 18, 2003 8:42 pm
Location: Somewhere they can't reach me, shoot me or electrocute me...

Post by Area54 »

I would put in the inline oiler and separator, that way you have more control over the lubrication system. The compressors need a little more work internally than just putting on a grease nipple.
Built, not bought.
Posts: 7230
Joined: Mon Oct 21, 2002 10:42 pm
Location: Brisbane

Post by MissDrew »

Like what?
Posts: 3523
Joined: Sun May 18, 2003 8:42 pm
Location: Somewhere they can't reach me, shoot me or electrocute me...

Post by Area54 »

Those questions can be best answered by the techs at Endless air. The compressors are internally modified to handle grease injection. Without modifications, I wonder where the grease goes? Grease does not easily vaporise... Grease also does not flow like suspended oil, so the compressor must be modded to some level to remain lubricated and also not pump the grease straight out the discharge port on the compressor.
Built, not bought.
Posts: 6021
Joined: Sat Feb 15, 2003 11:01 pm
Location: Shed.

Post by dumbdunce »

air lockers will engage at as low as about 35 psi, I've tested a few different models and they're fairly consistent. never tested the upper limits to see where the orings will blow out but wouldn't like to take them much higher than 110 psi (have bench tested to 110psi but not in a running vehicle) - although the ARB switch cuts out at 110 does it not? or is it 100?

there's no need to run your OBA up to 120psi, is there?

instead of shelling out for endless I'd be looking for a twin-cylinder compressor with integral sump from the wreckers - pick and payless charge around $40 for these guys and there are tons of them down there. spend a day building your bracket, mock it up in MDF and hot melt glue to get it right then go for the steel and welder.