Notice: We request that you don't just set up a new account at this time if you are a previous user.
If you used to be one of our moderators, please feel free to reach out to Chris via the facebook Outerlimits4x4 group and he will get you set back up with access should he need you.
Recovery:If you cannot access your old email address and don't remember your password, please click here to log a change of email address so you can do a password reset.

kill switch for Tuff Truck

General Tech Talk

Moderators: toaddog, TWISTY, V8Patrol, Moderators

Posts: 2136
Joined: Mon Dec 01, 2003 6:36 pm
Location: Lake Macquarie

Post by 4sum4 »

what about these old school big puppies

Image
[url=http://downunder4x4.net/forum/showthread.php?t=1650]86 Hilux[/url]
and a 84 extra cab



If Rocks Had P^ssies Our Lives Would Be Perfect :D...
Posts: 614
Joined: Tue Jul 27, 2004 7:47 pm
Location: Penrith

Post by UZJ40 »

do we need a kill switch for TT?
HoldFast RocKrawlin
Posts: 5803
Joined: Wed Feb 19, 2003 3:02 pm
Location: Brisbane

Post by ISUZUROVER »

UZJ40 wrote:do we need a kill switch for TT?
Did you read the FIRST POST??????????????????
_____________________________________________________________
RUFF wrote:Beally STFU Your becoming a real PITA.
Posts: 417
Joined: Wed Jul 13, 2005 8:30 pm
Location: NSW

Post by Modified Toy »

you could run a continious duty solenoid witch will handle the current draw and just have you red switch to turn the solenoid on and off
Posts: 2158
Joined: Sat Jan 20, 2007 8:16 am
Location: New Zealand

Post by KiwiBacon »

sierrajim wrote:Image

These are crap. Not rated for enough current draw.
I disagree.
I've put 511 amps through mine without problems. It is rated at 500amps for 5 seconds and 100 amps continuous on 24v.

Yo can buy larger versions which have a 5 second rating of 1200amps and continuous of 150amps on 24v.

The manufacturer of mine is Menbers of italy.
Their catalogue is a 10mb download: http://www.menbers.it/pdf/cat930_226_00.pdf
Posts: 1544
Joined: Tue Oct 22, 2002 8:37 am
Location: Performing booty fab in my Garage

Post by Wooders »

KiwiBacon wrote:
sierrajim wrote:Image

These are crap. Not rated for enough current draw.
I disagree.
I've put 511 amps through mine without problems. It is rated at 500amps for 5 seconds and 100 amps continuous on 24v.
But the contacts are crap quality - I'm just about to replace one because of the dodgy contacts.
AFAIK kill switches have been required for the last few TTC's - the last 2 at least.
And I noticed someone above said they were looking to mount on their bullbar - that's hard for driver/navi to reach when harnessed into position ;)
Lastly we wired ours off the negative, but so it kills EVERYTHING including the winch......basically my thoughts are if there is an electrical problem I'd like to shut everything down.
Cheers [url=http://www.wooders.com.au]Wooders[/url]
Posts: 4583
Joined: Fri Jun 11, 2004 5:57 pm
Location: Wheeling in my backyard

Post by sierrajim »

KiwiBacon wrote:
sierrajim wrote:Image

These are crap. Not rated for enough current draw.
I disagree.
I've put 511 amps through mine without problems. It is rated at 500amps for 5 seconds and 100 amps continuous on 24v.

Yo can buy larger versions which have a 5 second rating of 1200amps and continuous of 150amps on 24v.

The manufacturer of mine is Menbers of italy.
Their catalogue is a 10mb download: http://www.menbers.it/pdf/cat930_226_00.pdf
So how many amps would your vehicle draw with the following on at once doing a LONG winch at night:
-winch
-park lights
-thermo fan

Bearing in mind that you winch for more than 5 seconds at a time, if the switch fails your vehicle stops dead and you are not allowed to compete if you've bypassed the switch to keep going in the case of failure.
[quote="Harb"]Well I'm guessing that they didn't think everyone would carry on like a big bunch of sooky girls over it like they have........[/quote]
Posts: 2590
Joined: Tue Jan 04, 2005 11:33 am
Location: Brisbane

Post by Chucky »

Wooders wrote:But the contacts are crap quality - I'm just about to replace one because of the dodgy contacts.
AFAIK kill switches have been required for the last few TTC's - the last 2 at least.
And I noticed someone above said they were looking to mount on their bullbar - that's hard for driver/navi to reach when harnessed into position ;)
Lastly we wired ours off the negative, but so it kills EVERYTHING including the winch......basically my thoughts are if there is an electrical problem I'd like to shut everything down.
Just run two or three switches in series.
If any one of them gets pressed everything will still shut down.
And it wouldn't take too much more effort to run one on the b/bar as well as one in the cab as just one int he cab.

I have heard of a remote control activated kill switch. An offical gets the remote and if the car starts getting out of control (roll's or whatever) he can kill everything with a simple press of the button.
They wern't that expensive either.
My Cruiser is Environmentally Friendly.

It runs on recycled Dinosaurs.
Posts: 4583
Joined: Fri Jun 11, 2004 5:57 pm
Location: Wheeling in my backyard

Post by sierrajim »

Chucky wrote:
Wooders wrote:But the contacts are crap quality - I'm just about to replace one because of the dodgy contacts.
AFAIK kill switches have been required for the last few TTC's - the last 2 at least.
And I noticed someone above said they were looking to mount on their bullbar - that's hard for driver/navi to reach when harnessed into position ;)
Lastly we wired ours off the negative, but so it kills EVERYTHING including the winch......basically my thoughts are if there is an electrical problem I'd like to shut everything down.
Just run two or three switches in series.
If any one of them gets pressed everything will still shut down.
And it wouldn't take too much more effort to run one on the b/bar as well as one in the cab as just one int he cab.

I have heard of a remote control activated kill switch. An offical gets the remote and if the car starts getting out of control (roll's or whatever) he can kill everything with a simple press of the button.
They wern't that expensive either.
They run these in Monster trucks to lessen the chance of one going over a barrier into the crowd in the case of a driver being knocked out.
[quote="Harb"]Well I'm guessing that they didn't think everyone would carry on like a big bunch of sooky girls over it like they have........[/quote]
Posts: 2158
Joined: Sat Jan 20, 2007 8:16 am
Location: New Zealand

Post by KiwiBacon »

sierrajim wrote: So how many amps would your vehicle draw with the following on at once doing a LONG winch at night:
-winch
-park lights
-thermo fan

Bearing in mind that you winch for more than 5 seconds at a time, if the switch fails your vehicle stops dead and you are not allowed to compete if you've bypassed the switch to keep going in the case of failure.
I don't have a winch wired through it, so it's a moot point.
If I did, I'd have chosen the bigger switch. :D

How many amps does your winch draw? Park lights and thermo fan would only be about 30.
User avatar
A1
Posts: 3451
Joined: Tue Jan 28, 2003 8:57 pm
Location: NEWCASTLE

Post by A1 »

I'm looking at the second or third, the prob the third on this page from narva although its a bit large for I wanted .......

http://www.narva.com.au/Switches_15.html

And I will be wiring straight from the Pos to the switch to the donk /puter etc..........winch will be hard wired to batt .......
[b][i] DAN [/i] [/b]


:silly:
Posts: 1897
Joined: Thu Aug 05, 2004 6:24 am
Location: of the best barwork is at www.bolsys.com.au

Post by 80lsy gq »

the third one is the one that i have in my buggy Dan..and i have had no problems with it at all

dave
www.bolsys.com.au

the original and the best
Posts: 4275
Joined: Thu Dec 19, 2002 2:12 pm
Location: Sydney

Post by ozy1 »

jst an update here,

ive decided with my rig, thati am going to run a continours duty solenoid rated at 200Amps, then have one of the red ket switchis in my cab, that way reducing the need to run 2m of extra battry cable into the cab,

i measured the amp draw on all my wiring on the battery and on start up it pulls 170amps, and running it pulls heaps less, so i shouldnt have a drama,

but i do have a drama finding 00 or 000B&S cable,
User avatar
A1
Posts: 3451
Joined: Tue Jan 28, 2003 8:57 pm
Location: NEWCASTLE

Post by A1 »

Shawn,

I ended up getting the one I mentioned above which is

250 amp continuous/ 2500 intermittent for 5 secs

But because of lack or space to mount this in easy access for driver/navi ....and also because of the exposed studs at the rear ....I have since bought another type ..... :roll:

this one is rated @ 275amp continuous /1000 amp 10 secs, but is enclosed in a plastic enclosure that can be base mounted or through hole ( so the knob is only visible) ......and it was half the price of the first one I bought .......its only 70mm square x 90mm high and I can mount in a better posi .....

As for battery cable try a local welding shop and ask what size earth lead cable they keep ....this is flexible and most of the time double insulated ......Ive chased some up here 35mm2 in size for $7 a metre .......I was going to use some 70mm2 that I have @wrk but its physical size sucks ......

Dan
[b][i] DAN [/i] [/b]


:silly:
Posts: 2183
Joined: Sun Feb 27, 2005 4:15 pm
Location: newy

Post by evanstaniland »

A1 wrote:

this one is rated @ 275amp continuous /1000 amp 10 secs, but is enclosed in a plastic enclosure that can be base mounted or through hole ( so the knob is only visible) ......and it was half the price of the first one I bought .......its only 70mm square x 90mm high and I can mount in a better posi .....
hey Dan where did you get this particular switch and is there an internet page??
User avatar
A1
Posts: 3451
Joined: Tue Jan 28, 2003 8:57 pm
Location: NEWCASTLE

Post by A1 »

Ashdown's over near the sunnyside pub @broadmeadow .........I got trade prices due to my work having an account there :D


I just found this link ...strange thing is they only say 250amp here where on the inside of the actual switch it has 275amp ....then when you open the spec sheet that comes with it it says 225amp lol


doesnt matter the Little Vit wont draw that much continuous anyway

http://www.matson.com.au/switch_master.html


Dan
[b][i] DAN [/i] [/b]


:silly:
Post Reply

Who is online

Users browsing this forum: No registered users and 33 guests