kill switch for Tuff Truck
Moderators: toaddog, TWISTY, V8Patrol, Moderators
I disagree.sierrajim wrote:
These are crap. Not rated for enough current draw.
I've put 511 amps through mine without problems. It is rated at 500amps for 5 seconds and 100 amps continuous on 24v.
Yo can buy larger versions which have a 5 second rating of 1200amps and continuous of 150amps on 24v.
The manufacturer of mine is Menbers of italy.
Their catalogue is a 10mb download: http://www.menbers.it/pdf/cat930_226_00.pdf
But the contacts are crap quality - I'm just about to replace one because of the dodgy contacts.KiwiBacon wrote:I disagree.sierrajim wrote:
These are crap. Not rated for enough current draw.
I've put 511 amps through mine without problems. It is rated at 500amps for 5 seconds and 100 amps continuous on 24v.
AFAIK kill switches have been required for the last few TTC's - the last 2 at least.
And I noticed someone above said they were looking to mount on their bullbar - that's hard for driver/navi to reach when harnessed into position
Lastly we wired ours off the negative, but so it kills EVERYTHING including the winch......basically my thoughts are if there is an electrical problem I'd like to shut everything down.
Cheers [url=http://www.wooders.com.au]Wooders[/url]
So how many amps would your vehicle draw with the following on at once doing a LONG winch at night:KiwiBacon wrote:I disagree.sierrajim wrote:
These are crap. Not rated for enough current draw.
I've put 511 amps through mine without problems. It is rated at 500amps for 5 seconds and 100 amps continuous on 24v.
Yo can buy larger versions which have a 5 second rating of 1200amps and continuous of 150amps on 24v.
The manufacturer of mine is Menbers of italy.
Their catalogue is a 10mb download: http://www.menbers.it/pdf/cat930_226_00.pdf
-winch
-park lights
-thermo fan
Bearing in mind that you winch for more than 5 seconds at a time, if the switch fails your vehicle stops dead and you are not allowed to compete if you've bypassed the switch to keep going in the case of failure.
[quote="Harb"]Well I'm guessing that they didn't think everyone would carry on like a big bunch of sooky girls over it like they have........[/quote]
Just run two or three switches in series.Wooders wrote:But the contacts are crap quality - I'm just about to replace one because of the dodgy contacts.
AFAIK kill switches have been required for the last few TTC's - the last 2 at least.
And I noticed someone above said they were looking to mount on their bullbar - that's hard for driver/navi to reach when harnessed into position
Lastly we wired ours off the negative, but so it kills EVERYTHING including the winch......basically my thoughts are if there is an electrical problem I'd like to shut everything down.
If any one of them gets pressed everything will still shut down.
And it wouldn't take too much more effort to run one on the b/bar as well as one in the cab as just one int he cab.
I have heard of a remote control activated kill switch. An offical gets the remote and if the car starts getting out of control (roll's or whatever) he can kill everything with a simple press of the button.
They wern't that expensive either.
My Cruiser is Environmentally Friendly.
It runs on recycled Dinosaurs.
It runs on recycled Dinosaurs.
They run these in Monster trucks to lessen the chance of one going over a barrier into the crowd in the case of a driver being knocked out.Chucky wrote:Just run two or three switches in series.Wooders wrote:But the contacts are crap quality - I'm just about to replace one because of the dodgy contacts.
AFAIK kill switches have been required for the last few TTC's - the last 2 at least.
And I noticed someone above said they were looking to mount on their bullbar - that's hard for driver/navi to reach when harnessed into position
Lastly we wired ours off the negative, but so it kills EVERYTHING including the winch......basically my thoughts are if there is an electrical problem I'd like to shut everything down.
If any one of them gets pressed everything will still shut down.
And it wouldn't take too much more effort to run one on the b/bar as well as one in the cab as just one int he cab.
I have heard of a remote control activated kill switch. An offical gets the remote and if the car starts getting out of control (roll's or whatever) he can kill everything with a simple press of the button.
They wern't that expensive either.
[quote="Harb"]Well I'm guessing that they didn't think everyone would carry on like a big bunch of sooky girls over it like they have........[/quote]
I don't have a winch wired through it, so it's a moot point.sierrajim wrote: So how many amps would your vehicle draw with the following on at once doing a LONG winch at night:
-winch
-park lights
-thermo fan
Bearing in mind that you winch for more than 5 seconds at a time, if the switch fails your vehicle stops dead and you are not allowed to compete if you've bypassed the switch to keep going in the case of failure.
If I did, I'd have chosen the bigger switch.
How many amps does your winch draw? Park lights and thermo fan would only be about 30.
I'm looking at the second or third, the prob the third on this page from narva although its a bit large for I wanted .......
http://www.narva.com.au/Switches_15.html
And I will be wiring straight from the Pos to the switch to the donk /puter etc..........winch will be hard wired to batt .......
http://www.narva.com.au/Switches_15.html
And I will be wiring straight from the Pos to the switch to the donk /puter etc..........winch will be hard wired to batt .......
[b][i] DAN [/i] [/b]
:silly:
:silly:
jst an update here,
ive decided with my rig, thati am going to run a continours duty solenoid rated at 200Amps, then have one of the red ket switchis in my cab, that way reducing the need to run 2m of extra battry cable into the cab,
i measured the amp draw on all my wiring on the battery and on start up it pulls 170amps, and running it pulls heaps less, so i shouldnt have a drama,
but i do have a drama finding 00 or 000B&S cable,
ive decided with my rig, thati am going to run a continours duty solenoid rated at 200Amps, then have one of the red ket switchis in my cab, that way reducing the need to run 2m of extra battry cable into the cab,
i measured the amp draw on all my wiring on the battery and on start up it pulls 170amps, and running it pulls heaps less, so i shouldnt have a drama,
but i do have a drama finding 00 or 000B&S cable,
Shawn,
I ended up getting the one I mentioned above which is
250 amp continuous/ 2500 intermittent for 5 secs
But because of lack or space to mount this in easy access for driver/navi ....and also because of the exposed studs at the rear ....I have since bought another type .....
this one is rated @ 275amp continuous /1000 amp 10 secs, but is enclosed in a plastic enclosure that can be base mounted or through hole ( so the knob is only visible) ......and it was half the price of the first one I bought .......its only 70mm square x 90mm high and I can mount in a better posi .....
As for battery cable try a local welding shop and ask what size earth lead cable they keep ....this is flexible and most of the time double insulated ......Ive chased some up here 35mm2 in size for $7 a metre .......I was going to use some 70mm2 that I have @wrk but its physical size sucks ......
Dan
I ended up getting the one I mentioned above which is
250 amp continuous/ 2500 intermittent for 5 secs
But because of lack or space to mount this in easy access for driver/navi ....and also because of the exposed studs at the rear ....I have since bought another type .....
this one is rated @ 275amp continuous /1000 amp 10 secs, but is enclosed in a plastic enclosure that can be base mounted or through hole ( so the knob is only visible) ......and it was half the price of the first one I bought .......its only 70mm square x 90mm high and I can mount in a better posi .....
As for battery cable try a local welding shop and ask what size earth lead cable they keep ....this is flexible and most of the time double insulated ......Ive chased some up here 35mm2 in size for $7 a metre .......I was going to use some 70mm2 that I have @wrk but its physical size sucks ......
Dan
[b][i] DAN [/i] [/b]
:silly:
:silly:
hey Dan where did you get this particular switch and is there an internet page??A1 wrote:
this one is rated @ 275amp continuous /1000 amp 10 secs, but is enclosed in a plastic enclosure that can be base mounted or through hole ( so the knob is only visible) ......and it was half the price of the first one I bought .......its only 70mm square x 90mm high and I can mount in a better posi .....
Ashdown's over near the sunnyside pub @broadmeadow .........I got trade prices due to my work having an account there
I just found this link ...strange thing is they only say 250amp here where on the inside of the actual switch it has 275amp ....then when you open the spec sheet that comes with it it says 225amp lol
doesnt matter the Little Vit wont draw that much continuous anyway
http://www.matson.com.au/switch_master.html
Dan
I just found this link ...strange thing is they only say 250amp here where on the inside of the actual switch it has 275amp ....then when you open the spec sheet that comes with it it says 225amp lol
doesnt matter the Little Vit wont draw that much continuous anyway
http://www.matson.com.au/switch_master.html
Dan
[b][i] DAN [/i] [/b]
:silly:
:silly: