Post by ifslux »

I need some help with hooking up front and rear maxi drives, i have a pile of bits i got second hand and not real sure how it all goes to geather, as in all the air hoses and wiring. If anyone has any instructions or pictures of their setup, that would be really great.

Cheers
steve.
Posts: 266
Joined: Sun Jan 11, 2004 1:41 pm
Location: Brisbane

Post by Hobie18 »

think I still have the instructions, pm me your email address and I'll try to send them to you
Posts: 62
Joined: Wed Dec 09, 2009 8:32 pm
Location: bundaberg

Post by ifslux »

That would be great, thanks.
Posts: 5803
Joined: Wed Feb 19, 2003 3:02 pm
Location: Brisbane

Post by ISUZUROVER »

It is not hard.

There are 3 hoses and one wire. The wire sends -ve to the light.

For the 3 hoses, one is the breather, on is for activation, and one is for deactivation. Which is which depends on if you are using compressed air or vaccum.


If using compressed air, don't go above 20 psi.
_____________________________________________________________
RUFF wrote:Beally STFU Your becoming a real PITA.
Posts: 1143
Joined: Thu May 13, 2004 5:27 pm
Location: Quirindi, NSW

Post by bushy555 »

ISUZUROVER wrote:It is not hard.
If using compressed air, don't go above 20 psi.
Cool! So compressed air will work fine then for the actuators?
I have often thought about it over the past ten years on and off, and never have given it a go. Have been wanting to do it for ages.
Ive never liked the idea of vacuum since a line broke in the middle of a muddy creek and sucked in heaps of water and eventually the line blocked up with mud. Wasn't that an effort to clean out.
Bushies: http://www.angelfire.com/on4/bushy5560/ http://www.angelfire.com/on4/bushy5561/
Lightforce HID conversion stuff: http://www.angelfire.com/on4/bushy5551/
Posts: 369
Joined: Tue Sep 06, 2005 6:16 pm
Location: Melbourne

Post by RangingRover »

bushy555 wrote:
ISUZUROVER wrote:It is not hard.
If using compressed air, don't go above 20 psi.
Cool! So compressed air will work fine then for the actuators?
I have often thought about it over the past ten years on and off, and never have given it a go. Have been wanting to do it for ages.
Ive never liked the idea of vacuum since a line broke in the middle of a muddy creek and sucked in heaps of water and eventually the line blocked up with mud. Wasn't that an effort to clean out.
Realistically anthing that works off vacuum could be run off low pressure compressed air if you can hook it up backwards.... unfortunately the reverse isn't often true, since stuff that is designed to run on compressed air usually runs a decent amount of pressure!
84 Rangie, 3 inch spring lift, 2 inch body, Megasquirted 4.6, R380, rear Maxi, 34x11.5 JT2s. Simex FM installed.
Posts: 5803
Joined: Wed Feb 19, 2003 3:02 pm
Location: Brisbane

Post by ISUZUROVER »

bushy555 wrote:
ISUZUROVER wrote:It is not hard.
If using compressed air, don't go above 20 psi.
Cool! So compressed air will work fine then for the actuators?
I have often thought about it over the past ten years on and off, and never have given it a go. Have been wanting to do it for ages.
Ive never liked the idea of vacuum since a line broke in the middle of a muddy creek and sucked in heaps of water and eventually the line blocked up with mud. Wasn't that an effort to clean out.
Yep. I have been running mine on 15psi compressed air since new.
_____________________________________________________________
RUFF wrote:Beally STFU Your becoming a real PITA.
Posts: 1143
Joined: Thu May 13, 2004 5:27 pm
Location: Quirindi, NSW

Post by bushy555 »

ISUZUROVER wrote: Yep. I have been running mine on 15psi compressed air since new.
Sweet - thanks for the info on that. Another little project to undertake...