12mm head IP timing.

Tech Talk for Nissan owners.

Moderators: toaddog, V8Patrol

Post Reply
Posts: 314
Joined: Tue Aug 16, 2005 10:02 pm
Location: Ferntree Gully. Melbourne.

12mm head IP timing.

Post by Rhysta »

Guys with 12mm pumps, what have you got the timing set at?

Factory is .74..

Cheers Rhys
Posts: 345
Joined: Wed Dec 24, 2008 11:58 am
Location: Mackay

Re: 12mm head IP timing.

Post by tye1986 »

what ever the pump builder desgnates. mine is .55
gq coil cab with stuff
Posts: 61
Joined: Sat Jan 19, 2008 9:15 pm
Location: adelaide

Re: 12mm head IP timing.

Post by tim75b »

generally a lot less as the cam plate is a lot more aggressive talk to the pump builder and see what they recommend mine is .64 and as all these pumps are all built different depending on who builds them also injector cracking pressure plays a part in the base timming setting