welding 2mm box steel with 130 amp ARC

General Tech Talk

Moderators: toaddog, TWISTY, V8Patrol, Moderators

Post Reply
Posts: 257
Joined: Thu Nov 27, 2003 10:22 pm
Location: Stanthorpe- QLD

welding 2mm box steel with 130 amp ARC

Post by Snarba »

will this be enough oomf or will I need something bigger?
I've got a WEAPON OF MOSS DETRUCTION
Posts: 848
Joined: Fri Apr 02, 2004 12:01 pm
Location: Central Victoria

Post by Patroler »

im no expert but i reckon it should be enough
There are no stupid questions, but there are a LOT of inquisitive idiots
Posts: 4426
Joined: Mon Mar 22, 2004 4:39 pm
Location: Sunshine Coast

Post by bru21 »

seperate the joins my 1 mm or a touch more to allow full penetration. test on a scrap first.

cheers bru
ADHD Racing would like to thank
Mrs Bru @ Sunshine Coast Developmental Physiotherapy - www.scdphysio.com.au , Ryano @ Fourbys www.generaltire.com.au Blitzkrieg Motorsport
God of Magnificant Ideas!
Posts: 6774
Joined: Mon Aug 04, 2003 11:22 am
Location: Balls Deep

Post by V8Patrol »

bru21 wrote:seperate the joins my 1 mm or a touch more to allow full penetration. test on a scrap first.

cheers bru


OR.......

Tack it up and then run the grinder through each join so that the join is in a "V" shape. this is called a "V buttweld" and allows for full penetration.

130 amp and 2.5 rods will be fine.

Kingy
[color=blue][size=150][b]And your cry-baby, whinyassed opinion would be.....? [/b][/size][/color]
Posts: 141
Joined: Fri Nov 12, 2004 4:46 pm
Location: Newcastle

Post by mickbeny »

Hi all...If the wall thickness is only 2mm,I would say 130 amps is way to high for a 2.5 electrode.You need to be around a 100 amps or less,depending on the weld position.Dont bevel butt joints or have a gap,if your amps are set rite you will get good penetration,if you bevel butt or put gap you will blow a hole and mess the weld up.
PEACE...
Posts: 257
Joined: Thu Nov 27, 2003 10:22 pm
Location: Stanthorpe- QLD

Post by Snarba »

thanks everyone... off to weld stuff!!